Series 1000 Series 2000 Series M1 domino jolly frontiera explorer container shelter

Products

› Series M1

BROCHURE
SERIES M1

BROCHURE
M1 FIRE

Thanks to the experience, the great adaptability and the robustness of the modules destined for the military branches, New House has brought the same technology in the civilian sector with prefabricated mono-blocks of great versatility that allow to obtain highly qualified and performing constructions.

KEY STRENGTHS

Robustness, ease of installation, configuration variability and versatility of use distinguish the M1 module which - thanks to the ISO dimensions and the cast steel corner blocks - can be fitted in any way up to three overlapped levels. The units can be transported either assembled or disassembled, packed and stacked in packages of 4 or 5 units - flat-pack system - to reduce transport costs, yet ensuring ease of assembly.

  • Military area office complex Series M1
  • Italian Red Cross toilet facilities Series M1
  • Military accommodations series M1 with double-pitch roof
  • Laboratory series M1 with Domino outfitting
  • ComplessoTwo-story management office complex Series M1
  • Two-story school Series M1

DIMENSIONS

Lengths: 2,99 - 6,05 – 9,12 – 12,19 m
Width: 2,44 – 2,94 m
Inner heights: 2,30 – 2,50 – 2,70 – 3,00 m
Outer heights: 2,62 – 2,82 – 3,02 – 3,28 m
Other sizes are available upon customer’s request.

Module Series M1 m 2.94 x 6.05

Module Series M1 m 2.94 x 6.05

Modules M1 RENT RH15 stacked for office complex on three floors

Modules M1 RENT RH15 stacked for office complex on three floors

STRUCTURE

The prefabricated structure is made of galvanized steel profiles with a thickness of min. 2.5 mm, with the possibility to reach thicknesses up to 4.0 mm.

The vertical uprights are fixed by bolting to the relevant roof and base corner blocks made of steel and equipped with ISO drilling.

The transversal floor and covering bracing is made of tubular rods welded to the longitudinal profiles.

The standard painting in RAL 9002 color with single-component paint can be replaced with other colors upon request.

WALLS

The external and internal perimeter infill panels are made up of sandwich panels with variable thickness starting from 50 mm internally foamed with self-extinguishing polyurethane foam with galvanized and pre-painted micro-fretted sheets of various thicknesses available either smooth or embossed.

The junction of the panels is of a male-female dustproof type. The external walls have a minimum thickness of 50 mm.
The color of the wall panels, inside and outside, is RAL 9002 (white / gray) with the possibility of changing colors on customer request.

The wall panels can be dismantled by the customer and be repositioned at will to create configurations differing from the initial one.

Component packaging M1 to be shipped in flat-pack configuration

Component packaging M1 to be shipped in flat-pack configuration

Roof lift stage of module M1

Roof lift stage of module M1

ROOFING

Roof structure made of galvanized steel profiles, minimum thickness 2.5 mm, connected to the steel corner blocks.

The roof is made of insulated panels with a high water penetration thickness of 50 mm and a fret height of 40 mm.

The panels are appropriately sealed with gaskets and putty to further guarantee the rainwater seal.

The color of the panels is RAL 9002 (white/gray), it can be replaced with other colors upon request.

FLOOR BASEMENT

The floor structure is made of galvanized steel profiles with a min. 2.5 mm thickness welded to the corner steel blocks outfitted with ISO drilling.
In the welded areas a galvanization process is carried out.
The flooring is made of water-repellent chipboard sheets with a thickness of 18 mm. The decking is made of vinyl mats with a thickness of 1.5 mm, light gray color or similar. If any banks of toilet facilities are present, the floor panels are made of waterproof phenolic plywood.
Further customizable materials and solutions are available upon request.
Flooring
can be insulated with sandwich panels in polyurethane or mineral wool upon request.

Basement Series M1

Basement Series M1

Two-story office complex Series M1

Two-story office complex Series  M1

WINDOW AND DOOR FRAMES

Window and door frames are made of extruded aluminum or PVC profiles, RAL 9010 white color.

The windows have sliding opening, positioned on request, 3+3 mm glass, PVC roller shutters, water and dust seal with rubber seals.
The external doors are either flush or half-glazed with "frame/counter-frame" mounting system, positioned on request. Various accessories are available on request, such as opaque glass, double glazing, safety glass, blinds, shutters, insect screen, anti-panic bars, etc…

Windows and door frames together with the wall panels, can be dismantled by the customer and be repositioned at will to give rise to configurations different from the initial one.

WIRING

The electrical wiring will be executed with a general connection for external connections at 220 V - 50 Hz supplied with a certificate of electrical conformity to CEI standards in compliance with current safety standards.

The installation will be exposed, with self-extinguishing PVC pipes and flame-retardant and smoke-proof cables, mounted on the roof with unhooked drops to be fixed on site.

Interior lighting with 1x36 W neon ceiling lights, 1x36 W sockets, 10/A switch, electrical board with differential, ground cable. Other types of equipment and standard fittings can be supplied upon request

Executions on wiring

Executions on wiring

Customized restroom facilities equipment Series M1

Customized restroom facilities equipment Series M1

SANITARY-PLUMBING SYSTEM

The plumbing system will be built with exposed internal piping in propylene with thermo-welded joints and PVC.

Available equipment:
• ceramic and ABS sinks and washbasins with H/C water mixer
• ceramic toilet complete with accessories
• ceramic or ABS showers with curtains or box, fittings and mixer
• electric water heaters.

Pre-arrangement of connection to the wiring mains included.
Wall flush bank limit.
Stainless steel sanitaryware and methane/LPG water heater available on request.

SOME OPTIONALS

• Wall panels of various types and thicknesses
• Cladding panels
• Floor coatings and panels
• Colored and thermal break window and door frames
• Forks housings
• Conditioning and heating systems
• Roofing and canopies
• Walkways and stairs
• Stainless steel sanitaryware
• Protective casing for any pipes

Several other optionals available upon request.

Three-story external staircase Series M1

Three-story external staircase Series M1

Two-story management offices Series M1

Two-story management offices Series M1

TYPICAL USES

• Long-term building sites
• Offices and sales offices
• Temporary accommodations
• Toilet facilities
• Changing rooms and gymnasiums
• Dining halls
• Kitchens
• Recreational areas
• Kiosks
• Technical rooms
• Warehouses
• Self-service laundry rooms
and much more.